Chapter Five Specifications
Man_805U Rev 1.9 Page 47
Serial Ports
RS232 Port
DB9 female DCE
RTS/CTS/DTR/DCD hardware
signals provided
RS485 Port
2 pin terminal block
Typical distance 1.2 km
Data rate (bit/sec) -
configurable
1200, 2400, 4800, 9600,
14400, 19200, 38400,
57600, 76800, 115200
Byte format
7 or 8 data bits
Stop/start/parity bits configurable
System Parameters
Operating modes
Transparent mode
Controlled mode
Broadcast system
Addressed communications with
acknowledged
System address
Configurable 8 bit
User Configuration
Hayes commands from host
device.
Or via on-board DIP switches
Diagnostics
OK and PWR leds
Low signal receive led
CTS/RTS indication
RSSI measurement in
dBm
BER test